"NO AC" shown in the bottom right of the display indicates that the control panel is not receiving power. Use the following steps to resolve this issue.
- Ensure that the panel door is closed all the way. If it is not fully closed, the panel will not connect to the controller and receive power.
- Check the fuse. See "How do I Replace the Fuse?" for instructions on checking and replacing the fuse.
- Check the power source.
-
-
- If the controller is connected to an outlet, make sure is has power. You can test it using an electrical multimeter or another device you know is working.
- If the controller is connected to a GFCI/GFI outlet, reset the outlet.
- If the controller is directly wired into a power source, use an electrical multimeter to test the power.
-
While the NO AC is displayed, the controller is on 9V battery power and will not operate zones or run your system.