Note: This procedure will run the selected zone or program even if the controller is in rain delay or in an omitted time. |
Manually Running Programs:
To manually run all programs, simply press the up button while the controller's dial is set to the run position.
Manually Running Zones:
Running a Single Zone:
1.) Turn the dial to the Manual Zone position. Use the next and back button to cycle through zones. Use the up and down button to set the run time in one minute increments.
2.) When the desired run times are set, turn the dial to run.
Running all Zones:
1.) Turn the dial to the Manual Test position. Use the up and down buttons to set the run time for all zones in 10 second increments
2.) Turn the dial to run. The controller will now run all zones for the amount of time entered.