// MODELS & PRODUCT SPECIFICATIONS //
1” Valve – FIP Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz | 1” Valve – Slip x Slip Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz Inrush: 10.66 VA, Holding: 5.97 VA | 1” Valve – FIP with Flow Control Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz Inrush: 10.66 VA, Holding: 5.97 VA |
1” Valve – Slip x Slip with Flow Control Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz Inrush: 10.66 VA, Holding: 5.97 VA | E-100MB 1” Valve – Male x Barb Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz Inrush: 10.66 VA, Holding: 5.97 VA | E-100MBF 1” Valve – Male x Barb with Flow Control Dimensions 4.88” L x 3.25″ W x 5″ H (12.40 cm x 8.23 cm x 12.7 cm) Flow Range 0.2 to 35 GPM (0 to 8.5 m3/hr) Electrical 24VAC/60HZ Inrush: 9.48 V, Holding: 5.11 VA 24VAC/50Hz Inrush: 10.66 VA, Holding: 5.97 VA |
// ENDURO SERIES VALVE PRESSURE LOSS CHART //
| Imperial | Metric |
|---|
| Flow (GPM) | Loss (PSI) | Flow (m³/hr) | Loss (bar) |
|---|
| 0–4 | 1.2 max | 0–1.0 | 0.09 max |
| 4 | 1.2 | 1.0 | 0.09 |
| 6 | 1.7 | 1.5 | 0.14 |
| 8 | 2.5 | 2.0 | 0.19 |
| 10 | 3.0 | 2.5 | 0.22 |
| 12 | 3.4 | 3.0 | 0.25 |
| 14 | 3.8 | 3.5 | 0.28 |
| 16 | 4.1 | 4.0 | 0.30 |
| 18 | 4.4 | 4.5 | 0.32 |
| 20 | 4.6 | 5.0 | 0.33 |
| 22 | 4.8 | 5.5 | 0.35 |
| 24 | 5.1 | 6.0 | 0.38 |
| 26 | 5.4 | 6.5 | 0.41 |
| 28 | 5.8 | 7.0 | 0.45 |
| 30 | 6.3 | 7.5 | 0.47 |
| 32 | 6.6 | 8.0 | 0.50 |
| 35 | 7.3 | 8.5 | 0.51 |
Highlighted row indicates the low-flow maximum rating (0–4 GPM / 0–1.0 m³/hr).